Use the USB cable to connect the P900 data transmission to the computer, open the serial assistant software, press and hold the CONFIG and RESET buttons, release the reset button, then release the CONFIG button. The serial assistant pops up the “NO CARRIER ok” prompt to enter the configuration mode.

Note

Configuration mode interface baud rate is fixed 9600,If a late configuration error occurs, it can be reconfigured through the configuration mode.

Common parameters

Point-to-point communication configuration

Point-to-point mode Just copy the parameters below and paste them to the serial port assistant. Press the Enter key and then click Send. The configuration can be completed (the configuration succeeds with ok)

No Repeater

Master settings

  • ATS105:1
  • ATS140:2 ~ 65535
  • Set to Master mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 1, target address is 2.
  • Parameter
  • AT&F6
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=1
  • ATS140=2
  • AT&V
  • AT&W

Slave

  • ATS105:2 ~ 65535
  • ATS140:1
  • Set to slave mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 2, target address is 1.
  • Parameter
  • AT&F7
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=2
  • ATS140=1
  • AT&V
  • AT&W

Point-to-point transmission with repeater

Master

  • ATS105:1
  • ATS140:2 ~ 65535
  • Set to Master mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 1, target address is 2.
  • Parameter
  • AT&F6
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=1
  • ATS140=2
  • ATS141=1
  • AT&V
  • AT&W

Slave

  • ATS105:2
  • ATS140:2 ~ 65535
  • Set to slave mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 2, target address is 1.
  • Parameter
  • AT&F7
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=2
  • ATS118=3
  • ATS140=1
  • AT&V
  • AT&W

Repeater

  • ATS105:2 ~ 65535
  • ATS140:1
  • Set to Repeater mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 3, target address is 1.
  • Parameter
  • AT&F7
  • ATS101=1
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=3
  • ATS118=1
  • ATS140=1
  • AT&V
  • AT&W

Point-to-multipoint communication configuration

In the point-to-multipoint mode, just copy the parameters below and paste them into the serial port assistant, press the enter key and then click send to complete the configuration (the configuration is successful, and there will be ok after the configuration is successful)

Master settings

  • ATS105:1
  • ATS140:65535
  • Set to Master mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 1, target address is 65535.
  • AT&F1
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • AT&V
  • AT&W

Slave 1 settings ATS105:2 ~ 65535 ATS140:1

  • Set to slave mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 2, target address is 1.
  • AT&F2
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=2
  • ATS140=1
  • AT&V
  • AT&W

Slave 2 settings

  • ATS105:2 ~ 65535
  • ATS140:1
  • Set to slave mode, baud rate is 57600, link rate is 276000, network IP is 123456789, output power is 1000MW, device address is 3, target address is 1.
  • ATS102=2
  • ATS103=4
  • ATS104=123456789
  • ATS108=30
  • ATS105=3
  • ATS140=1