CUAV P8 Module User Manual

CUAV P8 User Manual 1 - CUAV P8 Module User Manual

Table of Contents

Product Definition

Indicator Light Definition

Configuration mode

establish  communication

Unmatched

ST Light: Red always on

Ground Unit

ST Light: pink flashing RSSI lamp: always on Sky Unit

ST Light: Green always on RSSI Light: always on

Ground Unit

ST Light: Always bright

RSSI : lights off Sky Unit

ST Light: Always bright

RSSI Light: Flashing

Button Definition

RESET Button

Restart the P8 Module

CONFIG Button

Pressing it alone is not defined. Press and hold the CONFIG and RESET Key at the same time. Release the

RESET key first, and then release the CONFIG key to enter the configuration state.

Power Requirement

Mount the antenna to the P8 before connecting power. Both the sky terminal and the ground terminal need to use an independent power supply instead of obtaining power from the controller. Please ensure that the maximum output current of the power supply is >2.5A (3~6s battery is recommended).

Default Configuration

The default configuration of P8 is: link rate (276000), interface baud rate 57600, broadcast mode. Generally speaking, P8 is plug and play, you don’t need to perform any configuration, just plug and play. If you need to modify the configuration, such as modifying the ID, setting point-to-multipoint, and relay mode, click the Configuration Guide.

Connect Controller

Use a special cable to connect the flight control interface [TELEM1]/[TELEM2] (some flight control interfaces are called Module), and the P8[Data] interface.

Ground Station Connection

Mission Planner

After connecting to the P8, select the correct port in the upper-right corner of the ground station, select 57600 baud rate, and click [CONNECT] to CONNECT to the ground station.
Port not recognized? After the P8 is connected, the mouse moves randomly and cannot communicate? Does the digital transmission indicator turn off and not work? For more information, please see FAQ]

QGroundControl

After data transmission is connected, open the QGroundControl and the ground station will automatically identify and connect. If it is not identified, you can manually add it as follows.
Click the icon in [QGroundControl]-[communication connection]-[add]

In the following interface, enter [name] [type] [serial port] and [baud rate], and click OK.

Select the connection you just added and Click Connect.

Product Specifications

Working frequency

840~845MHz

Spreading Method

Frequency Hopping/Fixed Frequency, GMSK, 2GFSK, 4GFSK, QPSK

Forward Error Correct

ion

Hamming, BCH, Golay, Reed-Solomon, Viterbi

Error Detection

32 bits of CRC, ARQ

Range

Reference distance: 40km

(The transmission distance is different under different en vironments/configurations, please refer to actual use)

Sensitivity

-109dBM@115.2kbps

-108dBm@172.8kbps

-106dBm@230.4kbps

Transit power

100mw~1000mw(20~30dBm); default:1000mW

Antenna gain

3DBi

Link Rate

345kbps Max

Baud rate

300bps  to 230kbps(57600)

Operating Modes

Point-to-Point, Repeat Mode

Input voltage

12V~60V

Input Current

>2.5A

Power consumption

Sleep: < 1mA (Future) Idle: 20mA Rx: 45mA to 98mA

Tx Peak: 2A

Interface

Antenna: SMA inner needle Serial:GHR-06V-S

USB: TYPE-C

Power: XT30PW-M

Operation Temperature

-40°C~85°C

Weight

P8 module;:55g Antenna:31g

 

Total: 86g

Size

65mm×40mm×18mm

Packing List

The package list is for reference only. The details are displayed on your purchase page.

Name

Sky Unit

Ground Unit

One Set

P8 Module

1

1

2

V5/X7 Series cable

1

1

Pixhack Data Cable

1

1

XT30-XT60 Power

Cable

1

1

XT30 Single-End Power Cable

1

1

840MHz Antenna

1

1

2

Type-C Cable

1

1

FAQ

Port is not recognized after connected to the computer?

Please install the Module driver

After connecting, the mouse moves and cannot communicate. What’s the matter?

Please power the Ground Unit first, and then power the sky Unit. If the data at the other end is transmitted to the USB when the USB is started, the computer will automatically install the Microsoft mouse driver.

Sometimes the P8 indicator will turn off does not work?

Please make sure that the maximum current input at the power port is greater than 2A; Otherwise, the P8 may be stopped; It is recommended that the ground unit use independent power supply instead of flight control power supply (connect V5 + flight control can not use independent power supply).

Follow us World Drone Market on our YouTube to view more about the CUAV P8.

Comments

0 Comments Add comment